1.1 SCOPE
This specification covers the design requirements and performance standard for the supply of optical fiber cable. This specification covers the general requirements and performance of cable which our offering including optical characteristics, mechanical characteristics and geometrical characteristics.
1.2 CABLE DESCRIPTION
Loose tube cable is a design that has high tensile strength and flexibility in a compact cable size. Our loose tube cable provides excellent optical transmission and physical performance.
1.3 QUALITY
We ensures a continuing level of quality in our cable products through several quality control programs including ISO 9001 and all the materials have passed REACH and ROHS.
1.4 RELIABILITY
We ensure product reliability through rigorous qualification testing of each product family. Both initial and periodic qualification testing are performed to assure the cable's performance and durability in the field environments.
1.5 REFERENCE
The cable which Our offering are designed, manufactured and tested according to international standards as follows:
|
IEC 60794-1-1 |
Optical fiber cables. Part 1: Generic specification |
|
IEC 60794-1-2 |
Generic specification- basic optical cable test procedures |
|
IEC 60793-3 |
Outer cables- sectional specification |
|
IEC 60794-3-20 |
Outdoor cables- family specification for optical self-supporting aerial telecommunication cables |
|
EIA/TIA 598 B |
Color code of fiber optic cables |
|
ITU-T G.650 |
Definition and test methods for the relevant parameters of single-mode fibers |
|
ITU-T G.652 |
Characteristics of a single-mode optical fiber cable |
|
ITU-T G.655 |
Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable |
2. OPTICAL FIBER
The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber primary protective coating. The detail data of optical fiber performance are shown in the following table.
OFS G.652 fiber use special spun device successfully controlled the value of PMD, and make sure that it keeps stable in cabling.
Approved by optical communication products ministry of quality supervision and inspection center, the connection between OFS fiber in and outside is good .The single-end connect-loss won’t be over 0.1dB and the double-end connect-loss is all little than 0.05dB.
Apply to non-relay communication network. Features: proof test >1%
OPTICAL FIBER CHARACTERISTICS (G.652 FIBER)
|
Category |
Description |
Specifications |
||
|
Before cabling |
After cabling |
|||
|
Optical Specifications |
Attenuation @1550 nm |
≤0.20 dB/km (max.) |
≤0.22 dB/km (max.) |
|
|
Attenuation @1625 nm |
≤0.23dB/km |
≤ 0.24 dB/km |
||
|
Zero Dispersion Wavelength |
≤1520 nm |
|||
|
Zero Dispersion Slope |
≤ 0.084 ps/nm2·km |
|||
|
Polarization Mode Dispersion(PMD) |
≤0.08 ps/km |
|||
|
Cable Cutoff Wavelength (λcc) |
≤1450 nm |
|||
|
Macro bending Loss (1 turn; Ф32 mm) @1550 nm (100 turns; Ф60 mm) @1625 nm (100 turns; Ф50 mm) @1310 &@1625 nm |
≤ 0.05 dB ≤ 0.05 dB ≤0.05 dB |
|||
|
Mode Field Diameter |
@1550 nm |
9.6±0.5μm |
||
|
DimensionSpecifications |
Cladding Diameter |
124.8 ±0.7μm |
||
|
Core/clad concentricity error |
≤0.6μm |
|||
|
Cladding Non-Circularity |
≤1.0% |
||
|
Mechanical Specifications |
Min bending radius |
12.5D (static) |
25D (dynamic) |
|
Proof Test level |
≥1.2% |
||
|
Fiber Curl Radius |
≥4.0m |
||
|
Peak Coating Strip Force |
0.9~6.8N |
||
CABLE STRUCTURE
|
3.1.1 DIMENSION AND PROPERTIES |
||
|
General properties |
Unit |
Value |
|
Fiber count (G.652) |
|
2-24 |
|
Max. No of loose tube |
|
1 |
|
Fiber No. per tube |
|
MAX 24 |
|
Loose tube |
mm |
2.0-2.5 |
|
Steel wire |
pc |
2 |
|
Armor |
material |
Corrugated steel tape |
|
Water blocking tape thickness |
mm |
0.2 |
|
Outer sheath material |
mm |
MDPE |
|
Cable OD |
mm |
9 ±0.3 |
|
Cable weight |
Kg/km |
|
|
Max. allowable pulling force |
N |
1500/600 |
|
Crush resistance |
N/100mm |
1000/300 |
Remark: The weight of zinc coating of steel wire surface shall be no less than 20 g/m2. Strand shall have a left lay.
|
3.1.2 WORKING CONDITIONS |
|
|
|
Temperature range |
Transport and storage:- 4℃ to +70℃ |
Min Bending Radius |
|
Installation:-10℃ to +60℃ |
Installation: 20 x OD |
|
|
Operation:-40℃ to +70℃ |
Operation: 10 x OD |
|
Note: 1. the nominal outer diameter may vary by ± 5%. 2. The nominal cable weight may vary by ±10%.